Availability: | |
---|---|
Quantity: | |
Mechanical-electric lift table.
No oil leaks. No hydraulic lift.
Maximum starting frequency 10 times per minute.
BuiIt-in charger. Compact, space-saving.
With 4 swiveI mute casters.
High strength pIasticwheeI carrier.
Quiet operation.
Model | YL-LA100D-01 | YL-LA100D-02 | YL-LA150D-01 | YL-LA150D-02 | YL-LA250-01 | YL-LA250-02 | |
Capacity | (kg) | 100 | 100 | 150 | 150 | 250 | 250 |
Table Size | (mm) | 800×500 | 910×610 | 800×500 | 910×610 | 800×500 | 910×610 |
Min. / Max. Table Height | (mm) | 410/1280 | 410/1280 | 410/1280 | 410/1280 | 355/830 | 355/830 |
Battery | 24DC-12Ah | 24DC-12Ah | 24DC-12Ah | 24DC-12Ah | 24DC-12Ah | 24DC-12Ah | |
Lifting Time without Load | (s) | 28-32 | 28-32 | 36-40 | 36-40 | 30-34 | 30-34 |
Lowering Time without load | (s) | 24-28 | 24-28 | 34-38 | 34-38 | 30-34 | 30-34 |
Lifting Time with Rates Load | (s) | 36-40 | 36-40 | 57-61 | 57-61 | 45-49 | 45-49 |
Lowering Time with Rates Load | (s) | 24-28 | 24-28 | 34-38 | 34-38 | 30-34 | 30-34 |
Max. Working Current | 6A | 6A | 8A | 8A | 5.5A | 5.5A | |
Charger | 24V-DC-2A | 24V-DC-2A | 24V-DC-2A | 24V-DC-2A | 24V-DC-2A | 24V-DC-2A | |
Working Cycle / Chartered | 130 | 130 | 70 | 70 | 140 | 140 | |
Max. Linear actuator force | (N) | 8000 | 8000 | 10000 | 10000 | 8000 | 8000 |
Mechanical-electric lift table.
No oil leaks. No hydraulic lift.
Maximum starting frequency 10 times per minute.
BuiIt-in charger. Compact, space-saving.
With 4 swiveI mute casters.
High strength pIasticwheeI carrier.
Quiet operation.
Model | YL-LA100D-01 | YL-LA100D-02 | YL-LA150D-01 | YL-LA150D-02 | YL-LA250-01 | YL-LA250-02 | |
Capacity | (kg) | 100 | 100 | 150 | 150 | 250 | 250 |
Table Size | (mm) | 800×500 | 910×610 | 800×500 | 910×610 | 800×500 | 910×610 |
Min. / Max. Table Height | (mm) | 410/1280 | 410/1280 | 410/1280 | 410/1280 | 355/830 | 355/830 |
Battery | 24DC-12Ah | 24DC-12Ah | 24DC-12Ah | 24DC-12Ah | 24DC-12Ah | 24DC-12Ah | |
Lifting Time without Load | (s) | 28-32 | 28-32 | 36-40 | 36-40 | 30-34 | 30-34 |
Lowering Time without load | (s) | 24-28 | 24-28 | 34-38 | 34-38 | 30-34 | 30-34 |
Lifting Time with Rates Load | (s) | 36-40 | 36-40 | 57-61 | 57-61 | 45-49 | 45-49 |
Lowering Time with Rates Load | (s) | 24-28 | 24-28 | 34-38 | 34-38 | 30-34 | 30-34 |
Max. Working Current | 6A | 6A | 8A | 8A | 5.5A | 5.5A | |
Charger | 24V-DC-2A | 24V-DC-2A | 24V-DC-2A | 24V-DC-2A | 24V-DC-2A | 24V-DC-2A | |
Working Cycle / Chartered | 130 | 130 | 70 | 70 | 140 | 140 | |
Max. Linear actuator force | (N) | 8000 | 8000 | 10000 | 10000 | 8000 | 8000 |